6. Display Codes
Table 1: Status Indications on the Terminal
Flashing pattern
Steady light.
Slow flashing light
without stop (1 flash
per second).
Short flashes (2
flashes per second).
1 flash with a long stop
(every 2. second).
2 flashes with a stop.
3 flashes with a stop.
4 flashes with a stop.
5 flashes with a stop.
6 flashes with a stop.
7 flashes with a stop.
The light emitting
diode "BAT" does not
light.
MAN-05-006
Operation and Maintenance Manual for MC-3-series
Description
Normal condition. The terminal is
turned on, the battery voltage is OK,
and no fault is detected.
Low battery voltage.
Programming mode.
Processor fault or test mode.
Indicates a processor module fault
and/or a processor fault.
Activity at start-up.
A joystick is out of centre position, or
a switch is in ON-position.
Radio fault.
Shutdown because of low battery
voltage.
Keyboard fault.
The terminal is not able to "read"
switches, joysticks etc.
Shutdown because of inactivity.
The terminal will soon "turn itself off"
since no switches, joysticks etc. has
been activated.
Priority stop.
The stop button or the shock
detector has been activated.
No LED
Action
None
Replace the battery with a fully charged
one.
Turn the terminal off and on again to
start normal operation.
Ensure that the processor module
BOOT-jumper is not turned on!
Replace the processor module and/or
the processor!
Set all switches/joysticks to OFF-
position and/or neutral position!
Change/Replace the Radio module.
Replace the battery with a fully charged
one.
There is a fault at the input module.
Turn the terminal off and on again to
start normal operation.
Ensure the Stop button is Out and turn
the terminal OFF and ON again to start
normal operation!
Ensure that there is a charged battery
in the terminal and that the terminal is
turned on. If the terminal has turned
itself off because of inactivity, turn it off
and on again to start normal operation.
Page 8 of 9