Controlling the relay with SMS messages
PwdCC
o
1234CC
Switches the relay ON
PwdDD
o
1234DD
Switches the relay OFF
The G-2000 has 2 digital inputs. When these inputs are activated, it sends SMS messages to users stored in
positions 1-6. It also switches the Siren output ON.
Input 1 is dedicated input for Gate or Door switch. When activated it sends SMS messages to users stored in
position 1 to 6.
Input 2 can be used to connect sensors such as PIR, smoke detectors, reed switches, etc. When activated it sends
an SMS message to users stored in positions 1-6 and it will call the 1
Arming the G-2000
PwdAA
o
Disarming the G-2000
PwdBB
o
Digital Input 1 is set as Normally Close (NC) and cannot be changed.
Change Digital input2 from NO to NC (Factory default is Normally Open ,NO)
PwdDIN2NC#
o
E.g. To change Input 2 from Normally Open (NO) to Normally Closed (NC), the following command is
needed
1234DIN2NC#
Program SMS message to be sent when input 1 or 2 is triggered.
PwdM1#sms content
o
PwdM2#sms content#
o
E.g If the user wishes to change the factory default message for input two to "kitchen window" the
following SMS command is needed.
1234M2#kitchen window#
Maximum of 32 characters
Checking the polarity of Input 1 & 2
PwdMQ#
o
When the inputs 1 & 2 are triggered, it will stay in alarmed status for 1 minute.
www.elsema.com
#( Input 1)
( Input 2)
Page 10
st
user.
ELSEMA
3G Receiver with relay output, G-2000