2easy CDV4791 Manuel d'installation - Page 15
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} 2easy CDV4791. 2easy CDV4791 19 pages. 1 user video entry kit
2 Easy 1 User Video Entry Kit
CDV4791/2
5.3 Electric Lock Connection
Lock connection using internal power output:
Note:
1. Elect ri c lock s must be Power-on-to-unlock .
2. The door lock output is limited to 12V with holding current maximum of 250mA.
3. The door lock output is not timed from the Exit Button(EB).
4. The unlock parameter of the monitor must be set to 0 (default).
Connecting one lock:
Jumper position in 1 & 2
BUS
EB
*
S1
S2
PL
S-
+
+
LOCK
Connecting two locks:
Jumper position in 1 & 2
BUS
PL
S1+
S2+
EB
2
nd
*
EB
1
ST
*
S-
2
nd
LOCK
1
ST
LOCK
15