2.3.1. Connection RF-MSG-DST
Input mains voltage
STAS3 slot for
STAK3 coupling
PE
1 Neutral conductor
2 L
3 nc (not connected)
PE
2.4. Establish wireless connection
1. Set the control unit and/or remote control or the button to teaching mode (obser-
ve the corresponding manual/data sheet)
2. Switch on the RF-MSG-DST voltage supply or briefly shut it off if the unit is al-
ready supplied with power.
3. For 5 minutes after connecting the voltage, the RF-MSG-DST will send a "Learn"
telegram every 10 seconds.
4. The wireless connection will be established automatically. For building control
systems, the display will display "Device is learning".
5. The RF-MSG-DST will stop sending "Learn" telegrams once the reply "Learned"
(for a learning process) or a control command is received (in the event of a power
interruption during operation).
2.5. Notes on mounting and commissioning
Device must not be exposed to water (rain). This could result in the electronic being
damaged. A relative air humidity of 95% must not be exceeded. Avoid bedewing.
2.6. Connection example
Mains connection wire and connection wires are available in different lengths as ac-
cessories.
Item numbers: Mains connection wire 60563 (5 m)
Connection wires 60565 (1 m), 60566 (2,5 m), 60567 (5 m)
Radio motor control unit RF-MSG-DST • Version: 28.06.2018 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • Technical Service: +49 (0) 7033 / 30945-250
Radio motor control unit RF-MSG-DST
Output
mains voltage
STAK3 coupling for
STAS3 plug
PE
1 Neutral
conductor
2 Up
3 Down
PE
Motor output
STAK3 coupling for
STAS3 plug
PE
1 Neutral conductor
2 Up
3 Down
PE