Cazoner J1 Manuel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Cazoner J1. Cazoner J1 2 pages. Natural gas detector

Equipment Maintenance
4
1. First time to use: Please aging it with electricity for more than
24 hours when first to be used after a long-distance transport
or long storage so that it can keep the best performance.
2.Self-checking period: Please self-test it for every 4-6
months.When you use an known concentration of gas to test
the detector to confirm whether it will work, please be sure the
operation environment is absolutely safe!
3. Cleaning: Please use soft brush,velvet cleaning tools to
clean its face end's dust or oil to ensure its detection hole
breathable so that can keep good display.Please do not use
detergents, bleach or other cleaning liquid to clean it.
Main Specifications
5
Model
J1
Applicable Gas
Natural Gas /LPG
Weight
100g
Sensor Type
Semiconductor
Overall Dimensions
59mm * 59mm * 40mm
Sampling Method
Natural diffusion
Working Voltage
AC90~260V
Range
0-100% LEL
Self-test Time
180s ± 10s
Alarm presetting
7%LEL
level
Visible and Audible alarm
Alarm
Working
Temperature: -20 to 40
Environment
Humidity: ≤ 95% RH (no frost)
Alarm Volume
70dB
5 years
Lifespan
7
After-sales service and Warranty Policy
SUPPORT ONE-YEAR FREE REPLACEMENT,BUT CAN NOT ENJOY
THE WARRANTY UNDER THE SITUATION OF NON-NORMAL USE
(FOR EXAMPLE: LIGHTNING, VOLTAGE INSTABILITY, WATER AND
OTHER HUMAN FACTORS)
4. Indoor use only: Please avoid rain or moisture when use it.
Please avoid it fall down. Do not beat,open or change it,or it
might causes the product failure.
5. Avoid volatile substances surround: Please do not use
volatile substances like alcohol or hair gel near to the detector.
If this kind of material causes the false report of the detector,
please ventilates promptly so that it can return to the normal
examination condition.
6. Lifespan: The maximum life of the detector is 5 years under
normal situation.Please replace a new one when over the use
of the period.
Common faults and solutions
6
Failure
Failure Analysis
Phenomenon
The connection
of the power cord
The green power
indicator does
not light
Power indicator
Press the self-test
button without
Circuit failure
sound and
light alarm
Pre-boot program
has not over yet
No response
to detection
of gas
Circuit failure
There are large
amount of volatile
organic compounds
After the
pre-start
procedure,
the detector has
been in the
Long storage
alarm state
Circuit failure
Solutions
Please check
thepower cord
connection and
is not well
connect it again
Please contact
the seller for
has failed
assistance
Please contact
the seller for
assistance
Wait for the
program to
complete the
pre-boot
Please contact
the seller for
assistance
Place the
detector
in a clean
air environment
andrestart the
surround
self-test
program
Continue to
aging it with
electricity
Please contact
the seller for
assistance