Dustbane 19677 Manuel d'utilisation - Page 15

Parcourez en ligne ou téléchargez le pdf Manuel d'utilisation pour {nom_de_la_catégorie} Dustbane 19677. Dustbane 19677 16 pages. Gladiator series

19. Control Panel Display codes

Safety code
C22
C14
FS0
SP1
Yellow led lit
Red led flashes
P1.X
P2.X
SF.X
X = A VALUE FROM "0" TO "9"

20. Programming

Your machine is factory programmed for optimum performance. It does not require further programming.
However, if you encounter one of the following codes; P1.x, P2.x or SF.x (x= a value from 0 to 9), use the
following programming instructions to reset your display. Operating the machine in a setting other than the
factory setting may cause machine failure. Machine damage due to improper programming will void your
warranty.
PROGRAMMING INSTRUCTIONS:
If your display reads P1.0 , P2.1 or SF.3 simply turn the main power off and back on again to reset display (these
are the factory programmed settings). If your display reads a value greater than stated above (ex. P1. " 5" , P2. " 7" ,
SF. " 9") continue to follow the instructions as described below
To reprogram the machine to the factory settings, turn the main power ON and press and hold the display
switch button (battery/time symbols) down for at least 3 seconds. P1.x will appear on the display. The P1 value
should read "0" (ex. P1.0). If the value is greater than "0", press the vacuum fan button until the display reads P1.0.
Press the display switch button again to advance to the next code. The P2.x value should read "1" (ex. P2.1). Press
the vacuum fan button to properly set. Press the display switch one more time to advance to the last code. This
code should read SF.3. If the value is not "3", press the filter shaker button until the display reads SF.3. To exist the
programming mode, turn machine off.
Cause
Short circuit brush protection:
stops all functions
Dissipater at high temperature. Activates if
temperature is over 194° F
Worn brushes
BRUSHES KO
Battery in reserve
Sweeping mode 1 button programming
activated
Sweeping mode 1 button
programming activated
Sweeping mode 2 button
programming activated
Filter shaker program setting activated
Actions to take
Reset by turning OFF the machine and
starting again
The machine resets when temperature lowers
under 176° F
Replace brush
Error can only be reset by turning off the
machine. This alarm condition arises if the
brushes are put in SHUTDOWN condition
three times in a minute.
Machine continues to work. Only a warning
that the battery is near discharge.
Machine stops all functions. Turn off machine
and charge the battery.
See programming
See programming
See programming
13