Contrast sensor
INSTRUCTION MANUAL
CONTROLS
OUT LED (yellow)
The yellow LED indicates the output status.
READY LED (green)
During functioning, the green LED permanently ON
indicates a normal operating condition; fast blinking
indicates an output overload condition.
DELAY LED (orange)
The orange LED ON indicates the timing function
activation on the digital output.
MARK PUSH-BUTTON
The mark detection procedure is activated by pressing
MARK push-button.
BKGD PUSH-BUTTON
The background detection procedure is activated by
pressing BKGD push-button.
See the "SETTING" paragraph for setup procedure
indications.
INSTALLATION
The sensor can be positioned using threaded M5 holes with max. 6 mm
depth.
Do not apply excessive torque when adjusting (max 2.2 Nm).
operating distance is measured starting from the front surface of the
The
sensor optics.
The reading direction can be changed inverting the cap and lens.
Mark detection on a reflective surface is improved adjusting the beam
direction to 5° ... 20° from surface axis.
CONNECTIONS
DIMENSIONS
TECHNICAL DATA
Power supply:
Ripple:
Current consumption
(output current excluded):
Output:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Delay:
Dark/light selection
Indicators:
Push-buttons:
DARK/LIGHT selection:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulating resistance:
Operating distance:
Depth of field:
Minimum spot dimension:
Emission type:
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU:
10...30 VDC limit values - Class 2 (UL508)
2 Vpp max.
50 mA max. @ 24Vcc
1 PNP output 1 NPN output
100 mA max.
 2 V
33 s
15 kHz
0 / 20 ms selectable (default configuration without delay)
automatic
OUT LED (yellow) / READY LED (green)/DELAY LED (orange)
MARK and BKGD push-buttons
Automatic (default configuration LIGHT mode)
-10 ... 55 °C
-20 ... 70 °C
500 VAC 1 min., between electronics and housing
>20 M 500 Vdc, between electronics and housing
9 mm
 3 mm
1.5x5 mm @ 9 mm
BLUE (465 nm) / GREEN (520 nm) / RED (630 nm) with automatic selection
According to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for each axis (EN60068-2-6)
11 ms (30 G) 6 shock for each axis (EN60068-2-27)
ABS
PMMA
IP67
M12 4-pole connector
90 g. max.
II 3G EX nA II T6 ; II 3D EX tD A22 IP67 T85°C
SETTING
DETECTION (MARK-BACKGROUND)
- Position mark in front of the sensor light spot and
press MARK push-button until the READY LED
(green) turns OFF.
The sensor detects the mark alternating the red,
green and blue emissions.
Avoid mark movements during this phase.
- Position the background in front of the sensor light
spot and press BKGD push-button; the sensor
detects the mark alternating the red, green and
blue emissions. Avoid background movements
during this phase.
The DARK/LIGHT operating mode is automatically
selected by the sensor.
Dark mark - light background = Dark mode.
Light mark - dark background = Light mode.
If the READY LED (green) is permanently ON, the
detection is successful.
If the LED blinks slowly, the detection has failed due
to insufficient contrast.
The sensor returns to the previous setting by pressing one of the two push-
buttons.
DELAY SETTING
The DELAY extends to 20ms the minimum duration of the active output
allowing the slower interfacing systems to detect shorter pulses.
The active delay is signalled by the corresponding orange LED ON.
ON
OUT without DELAY
OFF
ON
OUT with DELAY
20ms
20ms
OFF
Delay activation
Press MARK and BKGD push-buttons contemporaneously
for 2 sec. until the DELAY LED turns ON.
Delay deactivation
Press MARK and BKGD push-buttons contemporaneously
for 2 sec. until the DELAY LED turns OFF.
OUTPUT OVERLOAD
The digital output overload is signalled by the rapid blinking of the READY
LED.
The sensors are NOT safety devices, and so MUST NOT be used in the safety control of the machines
where installed.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
The warranty period for this product is 36 months. See General Terms and Conditions of Sales for
further details.
Under current Italian and European laws, Datalogic is not obliged to take care of product
disposal at the end of its life. Datalogic recommends disposing of the product in compliance with
local laws or contacting authorised waste collection centres.
© 2007- 2017 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS RESERVED.  Without limiting the
rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a
retrieval system, or transmitted in any form or by any means, or for any purpose, without the express
written permission of Datalogic S.p.A. and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarks
and brands are property of their respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
826003273 Rev.D