Dusun DSW-080 Manuel de l'utilisateur - Page 10
Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Dusun DSW-080. Dusun DSW-080 18 pages.
Hangzhou Roombanker Technology Co., Ltd.
Environmental adaptability
9
9.1 Climate and environment adaptability
Carry out the climate and environment adaptability test on the product according to the following table. The
state should not change during the test. After the test, it should be able to work normally. After the salt spray test,
the surface of the metal parts of the electronic anti-theft lock should not be rusted
Item
Test condition
High temperature
temperature: 55℃±2℃
Low temperature
temperature: -10℃±3℃
Constant heat and
temperature: 40℃±2℃
humidity
Relative humidity: 90%±3%
Concentration of salt solution: 5%±0.1%
Temperature: 35℃±2℃
Salt spray
Mist absorption time: 15 minutes spray every 45 minutes
Salt fog precipitation:1.0mL/(h•80cm²)~2.0ml/(h•80cm²)
9.2 Mechanical adaptability
Carry out the mechanical environment adaptability test on the product according to the following table, and it
should work normally after the test. The mechanical parts and components in the product are not loose, and the
shell is not deformed or damaged.
Item
Sinusoidal vibration
Free fall drop
10 EMC
10.1 Electrostatic discharge immunity
The limit of electrostatic discharge immunity should meet the requirements of test level 3 in GB/T
17626.2-2018. The product should not malfunction during the test and should be able to work normally after the
test.
Hangzhou Roombanker Technology Co., Ltd.
Tel:86-571-86769027/8 8810480
Website: www.dusuniot.com
2
3
4
5
6
Test condition
Frequency range: 10Hz~150Hz
Acceleration: 5m/s²
Vibration direction: X, Y, Z three axes
Sweep rate: 1oct/min
Number of sweep cycles: 1
height: 1m
Geometric faces: 6
Number of drops on each side: 1
Whether to bring packaging: yes
www.dusunremotes.com
Sensor
NO
COM
NC
VCC
Floor 8, building A, Wantong center,
Hangzhou 310004, china
www.dusunlock.com
A DUSUN company
Sensor
NO
COM
NC
VCC
duration
status
4h
working
4h
working
48h
working
Non-wor
48h
king
status
working
non-working