Datamars Livestock Patura P15 Manuel d'entretien - Page 8
Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} Datamars Livestock Patura P15. Datamars Livestock Patura P15 18 pages. Battery 0.17 j, 0.33 j 9 v energizer value
Battery 0.17 J, 0.33 J 9 V Energizer Value Service Guide
Insert a known good battery. Test the energizer's output voltage and output energy. Measure the energizer's
pulse interval, see page 9. If the energizer passes these performance tests, advise the customer that their own
battery is likely to be faulty.
If any mechanical damage is apparent, repair or replace parts as required. See the parts list on page 1. To replace
the handle, see page 10. To replace the switch knob, see page 11.
Test the energizer's output voltage and output energy. Measure the energizer's pulse interval, see page 9.
All energizers except house brand models HB17 and HB33. If the energizer is faulty, replace the module and
output transformer (supplied in the case lid). See page 14.
House brand models HB17 and HB33 only - If the energizer is faulty and is still within its warranty period, supply
a replacement energizer. See page 14.
Issue 4, 08/2020
8 of 18