Maintaining the Option
To ensure trouble free operation, the Present Sensor should be cleaned after every 100,000 inches
(254,000 cm) of media use. (To easily track label usage, go to SYSTEM SETTINGS
COUNTERS in the printer's menu system.)
Clean the assembly as follows:
1. Turn 'Off' the Power Switch and unplug the power cord from the AC Receptacle. Raise the Access
Cover and remove the media from the printer.
2. Remove the Door, the Thumbscrew and the Present Sensor Assembly from the printer.
3. Clean the Sensors on the Present Sensor Assembly using compressed air or a soft brush.
Note: For cleaning heavy deposits, isopropyl alcohol can be used – provided it is carefully
applied using a cotton swab, and allowed to dry before reattaching the device.
4. Carefully press the Present Sensor Assembly into the Front Plate Connector and, using the
Thumbscrew, secure the assembly to the printer. Reload media, close the Access Cover, and
reinstall the Door to complete the cleaning procedure.
Sensors
Present Sensor
Assembly
5