Datamax A-Class A-4212 Informations sur l'installation - Page 2

Parcourez en ligne ou téléchargez le pdf Informations sur l'installation pour {nom_de_la_catégorie} Datamax A-Class A-4212. Datamax A-Class A-4212 2 pages. Datamax a-4212: operators manual

Pin
Signal
Signal
Jumper
[1]
#
Direction
1
Ground
JMP 8
N/A
2
+5 VDC
JMP 9
[2]
3
Start Of Print
4
Slew Label
Input
5
Toggle / Pause
N/A
6
Reprint
7
+24 VDC
N/A
8
Ground
9
Ribbon Low
10
Service Required
11
End Of Print
12
Media Out
Output
JMP 1
13
Ribbon Out
14
Data Ready
15
Option Fault
[1]
Signal directions are given relative to the printer.
[2]
If active with no current print job, "WAITING FOR DATA" will be displayed. Specifying a quantity of 9999 while keeping this signal ON will cause non-stop label printing, except in single label "Imaging Mode", which will cause the printer to stop between labels.
[3]
For setting details, see PRINTER OPTIONS / GPIO PORT.
[4]
Drawing more than .5 amps can cause unreliable printer operation.
GPI/O Port A Overview
Function /
Position
Description
Installed
Printer chassis is used.
Removed
Ground must be supplied.
Installed
Printer +5VDC is used (.5 amp maximum)
Removed
+5VDC must be supplied.
[3]
Programmable
Advances media until the signal goes HIGH and
then, if not in continuous mode, positions at the
next available TOF.
Pauses the printer when LOW.
N/A
Reprints the last label without changes; If
always LOW, results in non-stop printing.
Printer +24 VDC (1.5 amp maximum)
Printer chassis.
[1]
Programmable
. Signifies a RIBBON LOW
DIAMETER warning condition.
When inactive, outputs will
Evoked by occurrences listed under 'Fault
be pulled up to a voltage
[1]
Messages.'
Active LOW.
determined by this jumper
[1]
Programmable
. Signifies the End of Print
setting, where:
(EOP) process.
Evoked during an Out of Stock condition.
Pins 1 – 2 = +5VDC;
Active LOW.
Pins 2 – 3 = +24VDC; or,
Evoked during an Out of Ribbon condition.
None = A common
Active LOW.
external voltage (not to
Evoked when a label waits to be printed. After
exceed +30VDC) via
the Start of Print signal is received, printing
external pull-ups
begins. (For syncing with the print cycle, the
(providing a 20K ohm
End Of Print signal indicates print process
feedback path through
completion.) Active LOW.
any two outputs).
Evoked during a Linear Scanner or RFID fault
condition. Active LOW.
WARNING: Failure to properly configure the GPIO Port jumper settings may result in damage to the printer and / or applicator.
Pin
Signal and
Jumper
[1]
#
Direction
1
+5 VDC
JMP 11
2
Input 6
N/A
[4]
3
Input 3
N/A
Installed: Pins 1 – 2
4
Output 6
JMP 7
Installed: Pins 2 – 3
Installed: Pins 1 – 2
5
Output 3
JMP 4
Installed: Pins 2 – 3
6
Ground
JMP 10
7
Input 5
N/A
8
Input 2
N/A
Installed: Pins 1 – 2
9
Output 5
JMP 6
Installed: Pins 2 – 3
Installed: Pins 1 – 2
10
Output 2
JMP 3
Installed: Pins 2 – 3
11
+24 VDC
N/A
12
Input 4
N/A
13
Input 1
N/A
Installed: Pins 1 – 2
14
Output 4
JMP 5
Installed: Pins 2 – 3
Installed: Pins 1 – 2
15
Output 1
JMP 2
Installed: Pins 2 – 3
GPI/O Port B Overview
Function /
Position
Description
Installed
Printer +5VDC is used (.5 amp maximum).
Removed
+5VDC must be supplied.
N/A
Programmed input function.
N/A
Programmed input function.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
Removed
Determined by an external source and pull-ups, not exceed +30VDC.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
Removed
Determined by an external source and pull-ups, not exceed +30VDC.
Installed
Printer chassis is used.
Removed
Ground must be supplied.
N/A
Programmed input function.
N/A
Programmed input function.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
Removed
Determined by an external source and pull-ups, not exceed +30VDC.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
Removed
Determined by an external source and pull-ups, not exceed +30VDC.
N/A
Printer +24 VDC (1.5 amp maximum).
N/A
Programmed input function.
N/A
Programmed input function.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
Removed
Determined by an external source and pull-ups, not exceed +30VDC.
Programmed output function pulled-up to +5VDC.
Programmed output function pulled-up to +24VDC.
Removed
Determined by an external source and pull-ups, not exceed +30VDC.
[4]