Figure 5
Wit
h cooler
1. Remove cover and mount the cooler with 4 screws as shown in Figure 1.
2. Connect the A and B in Figure 3, unscrew hydraulic fitting B from tank. On coupling B is a
small washer inside the connector to be included when installing the connector in the cooler.
3. Mount non-return valve (18) as shown in Figure 5.
4. Connect A and B on the cooler (Figure 4) Be sure to insert the small washer.
5. Disconnect hose 1 and 2 from the cooler to the tank (Figure 4 and 5)
6. Connect the power cord to the electrical contact Dc 12 v. Blue are negative.The cooler
starts at about 50 degrees temperature. Remember to look for rotation when the fan starts.
7. Replace the cover