DVA GIX8V Manuel de démarrage rapide - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} DVA GIX8V. DVA GIX8V 5 pages. Automatic water softener volumetric
SETTINGS
The GIX volumetric softener series features the Logix 760 valve.
Thanks to their user-friendly approach, they can easily be set.
They have 4 buttons that are used to set current time,
regeneration time, the amount of salt to be used for a
regeneration cycle and water hardness data.
Once set, the volumetric softener will count the number of litres
flowing through it, and it will automatically carry out a
regeneration cycle when the resin is close to depletion.
Typically, during operation, its display shows the actual time, the
current date, and the number of litres remaining before a
regeneration cycle.
During a regeneration cycle, the display shows the time needed
before completion as well as the phase it is in.
It is possible to lock the displayed information so as to avoid any
hazardous data modification.
INSTALLATION INSTRUCTIONS:
We suggest installing the equipment:
A-NON-RETURN VALVE
B-OUTLET TAP
C-BY-PASS TAP
D-INLET TAP
E-OVERFLOW PIPE
F-UNLOADING PIPE
Install on the water outlet a check valve (A) (DVGW, DIN 1988
T2) to protect the water softener from a reverse flow of hot
water that could cause damage.