TROUBLESHOOTING GUIDE
FAULT
Pump
running
normally
pressure low on installation
Fluctuating pressure
Pressure low after period of normal
use
Pump noisy
Presence of water in oil
Water dripping from under pump
Oil dripping
July 2012
but
Pump sucking air
Valves sticking, dirt in valves
Unloader valve seat faulty
Nozzle incorrectly sized
Worn piston packing
Valves worn
Valves blocked
Pump sucking air
Worn piston packing
Nozzle worn
Suction or delivery
valves worn
Suction
blocked
Unloader valve seat worn
Worn piston packing
Cracked pistons as a result of
dry running
Air in suction
Broken or weak suction or
delivery valve spring
Foreign matter in valves
Worn bearings
Excessive
liquid
Oil seal worn
High humidity in air
Piston packing worn
Piston packing worn
Plunger retainer worn
Travel plug in use on pump
Oil seal worn
WARNING: CHECK OIL LEVEL IN PUMP REGULARLY
Raptor Electric Operator's Manual
CAUSE
or
delivery
valves
temperature
of
DO NOT OVERFILL
Australian Pump Industries
REMEDY
Check water supply and possibility
of air ingress
Check and clean or replace if
necessary
Check and replace
Check and replace
Check and replace
Check and replace
Check and clean out if necessary
Check water supply and air ingress
at joints in suction line
Check and replace
Check and replace
Check and replace
Check and clean if necessary
Check and replace if necessary
Check and replace if necessary
Replace pistons
C h e c k
w a t e r
s u p p l y
connections on suction line
Check and replace if necessary
Check and clean if necessary
Check and replace if necessary
Reduce temperature
Check and replace
Check and change oil twice as
often
Check and replace if necessary
Check and replace
Check and replace
Replace with breather plug
Check and replace
a n d
11