OVERSPEEDING
Do not operate machine at over 3200rpm (engine speed). Over speeding can cause serious pump
damage.
EXCESSIVE BYPASS
Do not run on excessive by-pass. Switch machine off within two minutes of ceasing operation as
excessive by-pass can cause heat build up in pump and subsequent damage. Excessive bypass running
voids warranty.
HIGH PRESSURE SETTING
The high pressure pump is factory set to operate at its rated pressure. DO NOT ADJUST. Tampering
with the pressure regulator will void warranty and can be DANGEROUS.
CHECK NOZZLE MONTHLY
If pressure drops off check nozzle for wear. Nozzles should be replaced on a regular basis (every month
for machines in regular use, every three months for machines used intermittently). Using the machine
with the incorrect nozzle size or worn nozzle will void warranty and can be DANGEROUS to the operator.
PRESSURE CLEANER DAILY CHECK LIST
Check pump oil level
,
Check engine oil level
,
Check nozzle for wear
,
Check all high pressure components for leaks:
,
gun/lance
,
HP hose
,
all fittings
,
Check water filter and clean if necessary
,
Check unloader, safety valve and thermal dump for leaks
,
,
THREE MONTHLY REGULAR SERVICE
All professional machines need to be thoroughly serviced every three months. The service involved should
include the engine manufacturer's recommendations (see separate Engine Manual) and the following;
Change pump oil
,
Change gearbox oil (if applicable)
,
Check filter for foreign debris
,
Check unloader, safety valve and thermal dump for leaks
,
Check all HP components for leaks: Gun/lance, HP hose and all fittings
,
Replace nozzles
,
Check gearbox to engine key for wear, if key is worn see your local Aussie Eco Clean Service
,
Department. NB Damage generated by worn keys is not covered by warranty.
To maintain the Bertolini pump warranty (three years from date of purchase), the pump must be serviced by an
authorised service agent every six months. Contact Aussie for your nearest agent.
LOOK AFTER YOUR MACHINE AND IT WILL LOOK AFTER YOU!
Aussie HP Accessories ... making light work of cleaning chores
WEAR PROTECTIVE GOGGLES & CLOTHING!
WARNING
SIX MONTHLY REGULAR SERVICE
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154
Ph: (02) 8865 3500 Fax: (02) 9894 4240
www.aussiepumps.com.au [email protected]