When the X.25 link is to be on an outgoing TCP session, the type would be set to orig. The IP
address would be specified by the dest parameter, and the TCP port at that IP address would be
specified by the dport parameter.
The numvcc parameter is the number of X.25 virtual circuits to be supported. The default is 16.
The win parameter specifies the LAPB window size to be used for transmission. The Window
size is always 8 frames for receive. The default transmission window size is 2 per the ITU
specification X.25.
The t1 parameter specifies the value of the T1 timer. The timer defaults to the recommendation of
the ITU specification X.25. It is provided as an option for non-standard configurations.
The n2 parameter specifies the value of the N2 retry counter. The value defaults to the
recommendation of the ITU specification X.25. It is provided as an option for non-standard
configurations.
2.3.6 V
C
IRTUAL
IRCUIT CONFIGURATION
Syntax: vc <vc#> [win=<#>] [svc=< pad|pass>] [type=<RCV|ORIG>]
[dest=<IP Address>] [dport=<TCP Port>]
The VC command is only visible when the application is logged in. The command is used to
configure a virtual circuit connection to a Virtual X.25 line.
The <VC#> parameter refers to the virtual circuit configured on the X.25 line. It has the range of 1
through the number of circuits configured.
When the X.25 virtual circuit is to be placed on an incoming TCP session, the type would be set
to rcv. The X.25 virtual circuit would reside at the TCP port specified by the base parameter
offset by its virtual circuit number.
When the X.25 virtual circuit is to be placed on an outgoing TCP session, the type would be set
to orig. The IP address would be specified by the dest parameter, and the TCP port at that IP
address would be specified by the dport parameter.
The win parameter refers to the packet layer window size to be used for transmission purposes.
It defaults to the value of 2 per the ITU Recommendation X.25.
The svc parameter allows the type of service to be performed on the virtual circuit. When the
value of PAD is selected, the virtual circuit is terminated in a X.3 PAD service. When the value of
PASS is selected, an X.25 pass-through service is selected.
2.3.7 C
PAD
ONFIGURING
PARAMETERS
Syntax: pad <vc #>[echo=<ON|OFF>] [fwd=< none|cr|all>] [idle=<#ticks>]
[break=<none|intr|reset|brkind>] [crlf=<none|rmt|vc|both>]
[inact=<# seconds>|OFF]
The PAD command is only visible when the application is logged in. The command is used to
configure the X.3 PAD parameters of a virtual circuit. These parameters have relevance only if
the service selected on the virtual circuit is PAD.
The <VC #> parameter refers to the virtual circuit configured on the X.25 line. It has the range of
one through the number of circuits configured.
The echo option refers to reference #2 in the X.3 parameter list. When set to OFF, the IP-PAD
will not echo characters back to the IP endpoint. When set to the value of ON, all characters are
to be echoed back to the IP source.