AUSSIE ECO-CLEAN Hurricane Manuel d'entretien - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel d'entretien pour {nom_de_la_catégorie} AUSSIE ECO-CLEAN Hurricane. AUSSIE ECO-CLEAN Hurricane 13 pages. Monsoon series high pressure blaster three phase models

SAFETY PRECAUTIONS - IMPORTANT

1.
NEVER direct the spray jet at any person or animal.
2.
NEVER direct spray jet at any surface that may contain asbestos material.
3.
NEVER hold a finger over the high pressure nozzle.
4.
NEVER direct the spray jet at the machine itself or any electrical equipment.
5.
After use release the pressure in the high pressure hose by operating the pistol
trigger.
6.
DO NOT attempt any mechanical repair. If you have a problem with your machine
contact your local Aussie Eco Clean Service Division, phone (02) 9894 4144.
7.
NEVER supply any liquid other than water to the water inlet.
8.
NEVER pull the high pressure hose if it has formed kinks or nooses.
9.
NEVER pull the hose over sharp objects.
10.
DO NOT attempt to disconnect any hose or coupling with pressure still in the hose.
11.
DO NOT operate the machine whilst standing on ladders, use a platform tower or
scaffolding.
12.
Children should NOT be allowed to use the machine.
13.
We recommend the use of safety goggles when using the machine, particularly
with the sand blasting attachment (optional accessory) or any application where
loose particles of stone or ``grit, etc. may be blown around by the pressure spray.

ASSEMBLY AND PREPARATION FOR USE

1.
Check the oil in the pump . Note separate reservoirs. With the
machine on a level surface the oil level should cover the red spot
in the oil level sight glass on the side of the machine. If
necessary, top up with SAE 30w 50 oil (non foaming type). Do
not mix different grades of oil as this may affect the machine=s
performance. If alternative oil is used, first empty out oil by
unscrewing drain plug in bottom of machine.
2.
Ensure breather plug is fitted to pump (yellow).
WARNING: Before operation ensure top mounted oil filler plug is
replaced by breather. Failure to fit breather and keep clean can
result in over pressuring of oil chamber (crank case) and can blow oil seals. This will void
warranty..
HEAVY DUTY LANCE: To assemble the lance, insert Section B into Section A and screw together and
check nozzles have been fitted to end of lance (C & D).

HIGH PRESSURE HOSE

Connect the high pressure hose to the threaded water outlet on
the side of the machine via a screw coupling. No spanners are
necessary.
Aussie Monsoon & Hurricane ... Operation & Maintenance Manual
A
B
High pressure
hose connection
Supply hose
Australian Pump Industries
C
D
3