Before starting the machine
OPERATE IN WELL VENTILATED AREAS ONLY.
1. Ensure machine is level
2. Turn on water supply.
3. Pull gun trigger until water starts to flow in a
steady steam then release trigger.
D.
Starting the engine
(refer to engine manual for more details)
Throttle ... fully open
Choke ... closed position
Fuel value open
1. Ensure fuel valve is open
2. Move the choke on the engine to the closed
position . If engine is warm, move choke half-way.
3. Turn engine ON/OFF switch to ON
4. Hold the gun trigger on.
HIGH PRESSURE SPRAY CAN PENETRATE THE SKIN AND CAUSE SERIOUS INJURY!
SHOULD SPRAY PENETRATE THE SKIN, SEEK MEDICAL ATTENTION IMMEDIATELY!
6
NEVER POINT THE SPRAY GUN AT YOURSELF, OTHER PEOPLE OR ANIMALS.
Aussie AB Scud Cadet Series ... Operation & Maintenance Manual
5. Start engine, pull the recoil starter grip lightly until
resistance is felt, then pull briskly.
6. After engine starts, release the gun trigger and
slowly open the choke.
7. Warm up engine for 3 minutes without load.
E.
Pressure washing
WEAR PROPER FACE PROTECTION WHEN OPERATING
PRESSURE WASHER!
AB Scud 30: single vario lance.
Low pressure
Fan jet adjustment
For high pressure jetting the black plastic lance
head should be pushed fully in. Rotate the
plastic head to adjust the angle of the spray jet.
When low pressure and high flow is required,
including detergent application, pull the plastic
lance head out until it clicks.
AB Scud 40: dual lance.
For high pressure jetting rotate side grip on dual
lance backwards until it stops. Fine control of
pressure/flow can be made with small
adjustments to the rotation of the grip. On the
single lance There is no pressure adjustment
available on single lance options.
When low pressure and high flow is required,
including detergent application, unwind grip
two complete turns. Adjust the detergent
control on the pump as required.
March 2018
High pressure