Aussie Pumps Eco Clean Super Indy Instructions d'utilisation et d'entretien - Page 15
Parcourez en ligne ou téléchargez le pdf Instructions d'utilisation et d'entretien pour {nom_de_la_catégorie} Aussie Pumps Eco Clean Super Indy. Aussie Pumps Eco Clean Super Indy 20 pages. High pressure washer
Before carrying out any operations, disconnect the water cleaner from the mains electricity supply via the omni-
!
FAULTS
When the switch is turned the cleaner
does not start.
No jet or leakage from high pressure
water circuit.
After 30 seconds, the water cleaner
stops. (DS Vers.).
The pump turns but does not reach the
rated pressure.
When the lance is turned on the pres-
sure falls and rises.
In by-pass or total stop phase, the water
cleaner shuts down. (DS Vers.).
When the thermostat reaches the cho-
sen temperature the boiler does not
light.
Water not hot enough.
Too much smoke from the flue.
Insufficient detergent suction.
Water leaks from head.
Presence of water in oil.
Burner is smoking.
TROUBLE-SHOOTING
polar switch or by unplugging the plug from the socket.
CAUSES
Faulty electric connection.
Thermal protection has tripped.
Faulty water circuit connection.
Clogged water filter.
Mains tap turned off.
Detergent tap turned on.
Water intake filter blocked.
Faulty water circuit connection.
Pressure regulation valve is set at
minimum.
Lance nozzle is worn.
Dirty or worn valves.
Detergent intake device on the lance is
turned on.
The nozzle is clogged or deformed.
Insufficient supply.
Micro-leaks of water from the high pres-
sure circuit.
No fuel.
Fuel filters are clogged.
Thermostat setting.
Clogged filters.
Boiler coil clogged with scale.
No fuel.
Incorrect combustion.
Impurities or water in the fuel.
Tap turned off.
No detergent in the tank.
Control on the lance not switched on.
Coil or pipe clogged.
Gasket worn.
Oil seal rings worn.
Water in the fuel tank.
Fuel pressure incorrect.
Air throttle adjusted incorrectly.
Electrodes positioned incorrectly.
Fuel nozzle dirty.
Fuel nozzle worn or damaged.
Heating coil blocked by soot.
Aussie Eco-Clean Super Indy Operating & Maintenance Manual - 2020
REMEDIES
Check the mains voltage.
Reset (if it trips again, apply to the
technical service centre).
Check it.
Clean it.
Turn it on.
Turn it off.
Clean it.
Check it.
Regulate it.
Apply to our technical service centre.
Apply to our technical service centre.
Turn it off.
Clean or consult our technical service
centre
Check it.
Contact Service Centre.
Check the fuel level in the tank and see
that the fuel intake circuit is clean (no
water).
Change the in-line filter.
Check it.
Clean the fuel filters.
Apply to our technical service centre.
Fill the fuel tank.
Clean the various fuel filters.
Empty the tank and clean it carefully.
Clean the various fuel filters too.
Turn it on.
Fill the detergent tank.
Set the control on the lance.
Apply to our technical service centre.
Apply to our technical service centre.
Apply to our technical service centre.
Empty fuel tank, clean and refill with
clean fuel.
Contact Distributor for service.
Contact Distributor for service.
Contact Distributor for service.
Contact Distributor for service.
Contact Distributor for service.
Clean heating coil.
|
15