AUSTEM ESS 3kW Manuel d'installation et d'utilisation - Page 18
Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} AUSTEM ESS 3kW. AUSTEM ESS 3kW 20 pages.
5.1 Product specification
Classification
Capacity(kW)
MPPT voltage range
Maximum input voltage
PV
Input control method
Maximum input current
Voltage
Battery
Maximum input current
Rated voltage
Rated frequency
Number of phase
AC Output
Harmonic distortion
Power factor
Current THD
TOPOLOGY
Inverter protection
Protection
Protection
Measurement
Control
Communication
Operating temperature range
Operating humidity range
Size(W/H/D)
5. Product specification
Characteristics and Specifications
3KW
MPPT(Maximum Power Point Tracking) control
48V
70A
100V / 200V / 220V / 230V / 240V
Single phase 2 wire
Less than 3% each, less than 5% of total
Transformer-less type
Input over voltage, Output over current, Overloaded, Overheat
Over voltage, Low voltage, Over frequency, Low frequency
Voltage, Current, Frequency, Run mode,
Temperature, External temperature.
DC – DC conversion, Dc – AC conversion, Voltage, Current, Frequency
RS485(Converter available)
-10°C
30 ~ 85%
446 X 630 X 150(mm)
5KW
100~400 Vdc
500 Vdc
15A
96V
60A
50Hz / 60Hz
Less than 5%
95% or more
~
+45°C
RH(No
condensation)