Items
Body
Control panel
Catch tray
10. Troubleshooting
Problems
Not lighting
Ignite the pilot
light but not the
main fire
<Table 2>
Methods
Wipe it with a soft cloth and mild
detergent;
Turn off valves when not in use; Wipe panel
and control valve knob with mild detergent.
Pull out catch tray from front body until the
equipment cools down. Clean grease and
other crumbs. Reinstall
after cleaning.
Warning:ifthecatchtrayispermitted to fill too
high, should be cleaned!
<Table 3>
Possible causes
1.Insufficientgaspressure in pipe
2.Nozzle occlusion
1.Insufficientgaspressure in pipe
2.The main fire nozzle
occlusion
3.Gas control valves have problems
4.The pilot light and the main fire's
distance is too far
5.Flame is too low
Times
daily
daily
Per use
Problem solving
1.Contact the local gas
supply dept.
2.Dredge nozzle
1.Contact the local gas
supply dept.
2.Dredge nozzle
3.Change
control valves
4.Adjust
distance of them
5.Adjust the height of the
pilot light
gas
the