I N S TA L L AT I O N
MOUNTING
When rack mounting, it is advisable to allow 1 rack space above and
below the amplifi er. When multiple amplifi ers are mounted in a rack,
exhaust fans should be used on the rack. Airfl ow for cooling the AMC30,
AMC60 & AMC120 is by convection from bottom to top. Airfl ow for cooling
the AMC250 is by fan from front to back.
OUTPUT
DISTANCE
100V
Up to 50m
50m–200m
Over 200m
70V
Up to 50m
50m–200m
Over 200m
4 ohm
Up to 10m
10m–30m
Over 30m
PA G E 6
AMC30
AWG26(0.12mm2)
AWG26(0.12mm2)
AWG24(0.2mm2)
AWG20(0.5mm2)
AWG18(0.75mm2)
AWG26(0.12mm2)
AWG20(0.5mm2)
AWG18(0.75mm2)
AWG18(0.75mm2)
AWG18(0.75mm2)
AWG18(0.75mm2)
AWG13(2.5mm2)
Not Recommended
Not Recommended
LINE OUTPUT
he LINE output XLR can be used to connect up to 6 booster amplifi ers. Balanced wiring
(shielded pair cable) is recommended.
TAPE OUTPUT
The TAPE output wiring should be kept as short as possible.
INPUT CONNECTIONS
For wiring balanced in, pin 2 is hot. Unbalanced wiring on the microphone inputs is not
recommended. Balanced input wiring (shielded pair cable) is recommended.
Unbalanced RCA wiring should be keep as short as possible.
A M C S E R I E S I N S TA L L AT I O N & O P E R AT I O N M A N U A L
OUTPUT CONNECTIONS
DIRECT OUTPUT
The output terminal strip accepts wire sizes from 16-22AWG
(1.5mm2 – 0.35mm2) or spade lugs.
The following table should be used as a guideline for cable sizes.
Regulations in your area may require different gauged wire and should
be checked before using.
WIRE SIZE
AMC60
AWG20(0.5mm2)
AWG24(0.2mm2)
AWG16(1.5mm2)
AWG13(2.5mm2)
NOTE: Only connect one output - either Distributed Line
or Low Impedance.
NOTE: When wiring the LINE output as unbalanced, Pin2 should
be wired as hot and Pin1 should be wired as ground/shield.
Do not wire Pin3.
AMC120
AWG24(0.2mm2)
AWG22(0.35mm2)
AWG18(0.75mm2)
AWG16(1.5mm2)
AWG16(1.5mm2)
AWG13(2.5mm2)
AWG22(0.35mm2)
AWG18(0.75mm2)
AWG16(1.5mm2)
AWG13(2.5mm2)
AWG13(2.5mm2)
AWG10(6.0mm2)
AWG18(0.75mm2)
AWG18(0.75mm2)
AWG13(2.5mm2)
AWG13(0.35mm2)
Not Recommended
Not Recommended
AMC250