1. TECHNICAL DATA
As a stove of construction type 1, it is possible to connect
it to the chimney together with an existing other stove or
another hearth for solid fuels, as long as the chimney
dimensioning calculation complies with DIN 4705, Part 3.
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
Smallest heating capacity
2. IMPORTANT INFORMATION
The installation and operation information given here is of
general nature
. National and European standards, local
and building regulations as well as fire prevention laws
must be observed during the operation of the stove.
General safety instructions for the
operation of your stove
•
Read the entire manual before starting up your stove
thoroughly and observe the caution notices.
•
Your heating unit must not be moved without
approved means of transport with sufficient load-bearing
capacity.
•
Your heating unit is not suitable to be used as a stand
or as a ladder.
•
Please keep in mind that your
stove's surface heats up considerably
during
operation.
We
recommend wearing a safety mitten
when operating your stove.
•
Attention – stove varnish is no rust prevention!
•
Make your children aware of this particular danger
and keep them at a distance from the heating unit
whenever it is in operation.
•
Only burn approved fuels and materials as listed in
the chapter "Clean Burning".
•
The burning or placing of flammable or explosive
materials, like empty spray cans, etc. into the firebox as
well as the storage of such materials in the immediate
vicinity of your heating unit is strictly forbidden due to the
danger of explosion.
•
Do not wear loose or flammable clothing when adding
fuel to the fire.
958 mm
433 mm
417 mm
110 kg
130 mm
4 kW
6 kW
2,5 kW
therefore
5
Room heating capacity (depending on
building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
accordance with DIN 4705, Part 2
Fluegas mass flow
Fluegas temperature
Minimum feed pressure
Nominal thermal output
•
Placing non-heat-resistant objects on the heating unit
or in the vicinity of the heating unit is forbidden.
•
Do not lay laundry onto the stove for drying. Laundry
hung up to dry must be kept at a safe distance from the stove
because of the danger of fire.
•
The wood stove Flok 2.0 is not suitable for long term
heating.
•
During the operation of your heating unit it is forbidden
to use flammable or explosive materials in the same or an
adjacent room to the one in which your heating unit is
located.
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2)
a > 800 mm
b > 150 mm
c > 100 mm
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
Make sure that the room in which the stove is set up has at
least one door or window into the outside or is directly
adjacent to such a room. Other fireplaces and extractor
hoods must not be operated in the same room as the stove
Floor load capacity
Make sure that the load capacity of the supporting
construction is sufficient to carry the weight of the entire unit
before the heating unit is installed.
34 - 88m³
closed
3,92 g/s
closed
343 °C
closed
12 Pa
at 0.8 times n.
10 Pa
ther. outp.
(Minimum