Austro Flamm Dexter Instructions pour l'utilisateur - Page 9
Parcourez en ligne ou téléchargez le pdf Instructions pour l'utilisateur pour {nom_de_la_catégorie} Austro Flamm Dexter. Austro Flamm Dexter 20 pages.
english
Heating in-between seasons
Heating the stove in between seasons, when the outside
temperatures are higher, the flue gases may not be able
to escape completely and this may lead to disturbances
in the chimney draught, especially if the temperatures
are rising suddenly. The stove has to be charged with
less wood and the primary air has to be increased so that
the wood can burn down faster (with visible flames) and
thus the chimney flue can stabilize.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description
Gasket hollow Ø 6x2260 mm
Gasket oval 16x8x2600 mm
Keramott
Description
Keramott baffle plate 2
Front Keramott base
Outside base Keramott corner l/r
Inside base Keramott corner r/l
Rear Keramott base
Vertical Keramott outside
Vertical Keramott corner
Vertical Keramott rear
Keramott baffle plate 1
Grate
Other parts
Description
Door complete
Door handle
Door glass – short side
Door glass – long side
Stove varnish
Glass cleaner ½ litre
Accessories
You can obtain floor plates made of glass or steel, care products or the Heat Memory System for heat storage from
your certified dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer. This will guarantee that your stove functions
properly and safely.
The fireplae must not be altered.
Maintenance
To clean the glass, please use a specialised product such as Thermohit glass cleaner. Lacquered surfaces are to be
cleaned only with a cloth (may be damp). Special cleaning agents should also be used for stainless steel surfaces
ATTENTION: Please avoid that the glass gasket comes into contact with water or detergents, as this will cause a
curing of the gasket and thus result in glass damage.
Only gaskets in good order ensure the proper function of your stove!
Part reference
Part reference
No.
Dexter L
Dexter R
11
718138
12
718763
Part reference
Part reference
No.
Dexter L
Dexter R
1
720429
720474
2
720421
3
720422
720471
4
720423
720472
5
720427
6
720424
720425
7
8
720426
720473
9
720428
-
716408
Part number
Part number
No.
Dexter L
Dexter R
720476
13
720430
14
361089
15
720433
719919
16
719235
-
650002
-
640070
7
Chimney fire
A chimney fire may occur, due to sooting and deposits in
the chimney, if impropes or humid fuel is used. In case of
a chimney fire close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have an
expert inspect your chimney for cracks and air-tightness
after the burning out of the chimney.
Dexter L
Keramott numbering = installation instructions!
Dexter
Dexter R
.