SPECIFICATIONS
Specification
Voltage
Current
Fuse
Bulb/Reflector
Shutter Timer
Foot Switch
Hour-Meter
Dimensions (L X W X H)
Weight
Wavelength
320-390 nm
390-450 nm
280-320 nm
** Measured with an EIT Spotcure Radiometer or Accu-Cal 50 radiometer using a Lightguide
Simulator and standard internal "Cool Blue" filter.
† Operating the unit at less than rated input voltage may yield less output intensity.
0.2
0.18
0.16
0.14
0.12
0.1
0.08
0.06
0.04
0.02
0
282
®
BlueWave
50 Light-Curing Spot Lamp
PN 38920
230 Vac., 50Hz
1 Amp
F2 Amp
50 Watt (pre-focused)
. 01 to 99.9 sec. electronic
programmable
Rocker type
LCD, bulb hours
12.0" X 12.25" X 6.5"
(30.5cm X 31.1cm X 16.5cm)
21 lbs. (9.5 kg)
Output Intensities (Typical)**
3.0+ W/cm²
2
3.5+ W/cm
2
1 W/cm
BlueWave 50 spectral output
305
328
351
Figure 3. 50W Spectral Chart
F3 Amp 5 x 20 mm IEC 127
50 Watt (pre-focused)
. 01 to 99.9 sec. electronic
(30.5cm X 31.1cm X 16.5cm)
†
374
397
420
Wavelength
PN 38925
115 Vac., 60 Hz
2 Amp
programmable
Rocker Type
LCD, bulb hours
12.0" X 12.25" X 6.5"
21 lbs. (9.5 kg)
443
466
489