GAC IGC700 Series Manuel - Page 6
Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} GAC IGC700 Series. GAC IGC700 Series 18 pages. Integral governor control
The Bar Graph displays the "approximate" percentage from 0 to 100%. Pressing the +/- arrow buttons,
increases or decreases the value. You may have to press the +/- button several times to illuminate the next
LED. This is due to the difference in resolution between the LED's and the actual parameter being
adjusted.
If only LED 0 is on, the
value is between 0%
and 9%.
EXAMPLE 1 – Bar Graph displaying between 50% and 59%.
EXAMPLE 2 – Code Flash mode displaying the number 1500.
All IGC values that are flashed out are always 4 digits. The LED's are labeled as 0, 1, 2,..,10.
Flash mode can display any value between 0 and 9999. They would be displayed by flashing 0-0-0-0 thru
9-9-9-9 respectively. Please review the example below of displaying the value 1500.
10
10
9
8
7
6
5
4
3
2
1
0
repeat
1
Bar Graph Display
&
Flash Codes
Bar Graph Display
10
9
8
7
6
5
4
3
2
1
0
Code Flash Mode
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
5
0
6
This indicates the value is
between 50% and 59%.
10
10
9
9
8
8
7
7
6
6
5
5
4
4
3
3
2
2
1
1
0
0
0
repeat
Code
10
9
8
7
6
5
4
3
2
1
0