GAF Master Flow PG2 Manuel d'instructions d'installation - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel d'instructions d'installation pour {nom_de_la_catégorie} GAF Master Flow PG2. GAF Master Flow PG2 7 pages. Power attic vent – gable mount

GAF Master Flow PG2 Manuel d'instructions d'installation
POWER ATTIC VENT
Gable Mount
Always read and observe safety considerations and installation instructions.
Safety Considerations & Warnings
1. Use this unit only in the manner intended by GAF.
If you have any installation questions, please contact
Master Flow
Technical Services at 1-800-211-9612.
®
2. For general ventilating use only. This ventilator has an
unguarded impeller. Do NOT use in locations readily
accessible to people or animals.
3. Do NOT use to exhaust hazardous material, dust,
or combustible vapors.
4. During installation, always wear appropriate safety
glasses, gloves, hard hats, restraints, and other safety
equipment to avoid injury. Warning: Always wear
durable work gloves while handling the unit.
5. Observe all applicable building and electrical codes.
6. Installation work and electrical wiring should be done by
a qualiied person in accordance with all building codes
and the National Electrical Code (U.S. only), including
codes for ire ratings. Contact a qualiied electrician if
you are not comfortable or familiar with electrical codes
and/or installations.

Tools Required

/
" or Adjustable Wrench
3
8
• #2 Phillips Screwdriver
• Saw (if installation requires
additional wood supports)
• Safety Eyewear
• Fall Restraint Equipment
Figure 1a
©2015 GAF 6/15
1 Campus Drive, Parsippany, NJ 07054
• Hard Hat and other
Safety Equipment
• Utility Knife
• Gloves
• Ladder
• Claw Hammer
Figure 1b
Nut
Bolt
Shroud
Mounting
Brackets
Installation Instructions
For Gable-Mount Models: PG2, PG3,
EGV5 & EGV6
7. The ventilator should be connected to a 120 volt, 60 Hz
grounded circuit only with minimum 14-gauge wiring
that has at least 3 amperes of available capacity. If you
cannot conirm there is suficient electrical capacity on
an existing circuit, install a separate dedicated circuit.
Do NOT use an extension cord to operate.
8. Inspect for hidden utilities before cutting or drilling.
Do NOT damage electrical wiring or other hidden
utilities when cutting or drilling.
9. Make sure the fan blade is on tight and ensure the set
screw is securely tightened.
10. Ducted fans must always be vented to the outdoors.
11. FOR HOMES WITH A GAS OR OIL FURNACE OR
APPLIANCE LOCATED IN THE SAME SPACE:
The ventilator MUST be wired with a switch or other
interlocking device to prevent the furnace and ventilator
from operating at the same time during the heating
cycle. The switch or other interlocking device MUST
disconnect the vent unit from the electrical circuit power.
GAF recommends that the switch (not included) be
installed by a qualiied person in accordance with all
applicable building codes and standards.
• Pencil or Marker
• Tape Measure
/
" Trade Size Cable
1
2
Clamp Connector
• Type NM Electrical Cable
• Wire Nuts
Figure 2a
Figure 2b
V971382
F