Additional Actuator Assy (VP1316) functions:
Note: The installation tool has two additional functions that are controlled with the actuator assy (VP1316).
1.
Service position: Press the actuator assy (VP1316) for five seconds (until the white LED on the tool starts to flash (1 /sec) and release
again. The installation tool remains in the rearmost position. The anvil insert can now be easily changed or the clamping jaws
serviced. Press the actuator assy (VP1316) briefly and the tool moves to its starting position again.
2.
Auto and Manual mode:
a. In Manual mode, hold the actuator assy (VP1316), depressing during setting of the fastener until the mandrel is sheared o ff.
b. In Auto mode, you only have to press the actuator assy (VP1316) briefly and the installation tool controls the fastening
process automatically.
3.
To change from one mode to the other, hold the actuator assy (VP1316) pressed for ten seconds (until the white LED on the too l starts
to flash (2 sec.) and release again. Press the actuator assy (VP1316) briefly and the tool moves to its starting position again.
Attaching the Belt Clip (VP1322):
Note: Always ensure belt clip (VP1322) is secure to the installation tool before using.
1.
Attach the belt clip (VP1322) to the foot of the installation tool using the screw. A corresponding thread and slots are recessed in the foot
of the housing on both sides of the installation tool.
2.
Check at regular intervals that the belt clip (VP1322) is still securely attached. Otherwise, retighten the screw.
SLOTS FOR BELT CLIP (VP1322) (2X)
BELT CLIP (VP1322)
Battery (VP1309) Storage:
1.
Protect the battery (VP1309) from moisture and liquids. Do not leave in car e.g. in the summer.
2.
Store the battery (VP1309) only in optimum temperature range between -22°F (-30°C) and 77°F (25°C). The batteries can be stored as
follows without recharging:
Storage period between 22°F (-30°C) and 77°F (25°C) = 1.5 years
Storage period between 22°F (-30°C) and 113°F (45°C) = 3 months
Storage period between 22°F (-30°C) and 140°F (60°C) = 1 month
3.
A significantly shorter operating time after recharging indicates that the battery (VP1309) is worn out and needs to be replaced.
Observe all local disposal procedures.
GB106 16V BATTERY INSTALLATION TOOL SN: 1067 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
HOW TO SET-UP THE GB106 Cont.
SCREW