WARNING:
Only qualified and trained operators shall install, adjust or use the assembly power tool for non-threaded
mechanical fasteners.
WARNING:
Operator
WARNING:
I
t is required that eye protection, hearing protection and safety boots be worn at all times while handling this equipment.
WARNING:
The users or the user's employer must assess specific risks that could be present as a result after each use
based on their application.
● Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any
moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
● Verify that hydraulic hose fittings and couplings, air and electrical connections are secure.
● Verify
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool.
Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start-up.
WARNING:
Do not operate this tool without deflector, pintail catcher bag or pintail collection bottle in place.
CAUTION:
Do not use beyond the design intent.
The powerunit is shipped with a red plastic plug in the air inlet connector. The connector has a 1/4 - 18 NPT female pipe thread to accept
end-user air hose fitting. The tool & powerunit comes with oil and is ready to use.
1. Remove red plastic shipping plug from air inlet on regulator (A-1291) and screw in your quick disconnect (air) fitting.
2. Open cap on top of oil reservoir and fill with AW-32 oil or equivalent to approximately 3/4 full, if required.
3. Connect the installation tools hydraulic line, air line and vacuum line to powerunit. (Make sure all connections are secure).
4. Connect clean dry air supply using 1/2" (12.7 mm) air line min. Set air pressure to 90 - 100 P.S.I. (6.2 - 6.9 bar) Max. on (A-1291) regulator.
5. Cycle tool five times.
6. Disconnect air supply.
7. Attach nose assembly. (Apply Vibra-tite® pt. #405125 to all threads on nose assembly and allow it to set 20 minutes prior to assembly).
8. Reconnect air supply.
VACUUM TUBE FROM
TOOL INTO FITTING
AIR LINE FROM TOOL
AIR OUTLET
HYDRAULIC LINE
FROM TOOL
HYDRAULIC OUTLET
GB743SHAVT/6NF
HOW TO SET-UP THE GB743RAVT
MUST
read and understand all warnings and cautions.
the air lines and/or hydraulic hoses are not a trip hazard.
(Image may not reflect actual tool)
GB808V Powerunit
8
A-1291 REGULATOR
A-204 RED SHIPPING PLUG
USER QUICK
DISCONNECT FITTING
1/2" (12.7 mm)
AIR HOSE
AIR INLET
10/22 REV 3/23