Cause
code
E01
No sensor signal
Over‐voltage protection of the
E02
motor
E03
Over‐current protection
E04
Open circuit
E06
Message failure
E07
Emergency switch off
TROUBLESHOOTING GUIDE
Checking
1. Check the distance and
place between sensor and
magnet.
2. Check if the wire is broken.
3. Check if the magnetism is
good.
4. Check if the controller is
damaged.
1. Check if the network
voltage is stable.
2. Check if the controller is
damaged.
1. The machine is overloaded.
2. Check if the motor or the
roller gets stuck by
something.
3. Check roller lubrication.
4. Check if the controller is
damaged.
5. Check if the motor is
damaged.
1. Check the wires of the
motor are connected well.
2. Check if the motor is
open‐circuit.
3. Check if the controller is
open‐circuit.
1. Check if the connecting
wires are plugged well.
2. Check if the connecting
wires are broken.
3. Check if the console is
broken.
4. Check if the controller is
damaged.
1. Check if the emergency
switch is attached.
~ 12 ~
Correction
1. Adjust the distance
between the sensor and the
magnet.
2. Change the wire.
3. Change the magnet.
4. Change to a new controller.
1. Regulator is needed to
adjust the voltage.
2. Change to a new controller.
1. Verify user weight is within
allowed parameters
2. Take the foreign matter
out.
3. Lubricate the roller.
4. Change to a new controller.
5. Change to a new motor.
1. Connect the motor wires
properly.
2. Change to a new motor.
3. Change to a new controller.
1. Plug all the wires properly.
2. Change to the new wires.
3. Change to a new console.
4. Change to a new controller.
1. Attached the emergency
switch.