9.
OPERATION
Through the PHI6 Explorer soft panel the user can interface with the YAV90304 board
manually. This tool is a very useful for table-top debugging of test-systems or system
maintenance on-site.
Activate relays
By clicking a relay in the panel, the relay closes and
its status in the panel is updated.
Reset: Reset button will put all relays in 'Open'
status.
Config tags
To operate with Phi6 driver each relay must be given
a tag name. By clicking this button, the panel will
change its background color from grey to yellow, and
tag name can be modified.