Lights must be placed vertically upward. The shortest distance between working lights must be
more than or equal to 900mm. Layout the lighting installation as shown above..
5.3 Data cable
Data cable is DMX512 signal
Signal line connections is X-type connector, X-type connector-----If the external flexible cable or cord of
this light is damaged, please replace professional cable or cord from the manufacture or its agent.Lights'
DMX input and output connects to a three-pin XLR, first pin is grounded, then negative signal is second
pin, third pin connects to the positive polarity signal.
In order to prevent reception reflection and interference control signal, a terminal plug must be installed
on the first branch of the connected device last 3-pin output jack.
3XLR plug
The controller connects to the nearest input XLR 3-pin, then from the output of the device connects to
the input of the next device, continuous connection one by one, the final output data cable terminal
equipment plug one end into the terminal.
If the signal transmission is long-distance , 512 signal amplifier must be
added. DMX512 signal controller connect to the input of the amplifier first,
then connect to the fixture from its output, couple with the terminal plug last.
Terminal plug connect with XLR plug second or
1.Grounding
third by a 0.25w 120ohm resistor, then connect
the resistor into last light's DMX output jack
2.Signal-
3.Signal+