Airconet HP240 Manuel d'installation - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Airconet HP240. Airconet HP240 3 pages.
7. Setup the thermostat:
C →
a)
o
0
F
Temperature mode select:
o
F is Fahrenheit (not compatible with App)
o
C is Celsius (default)
ΞS → Ξ0 → Ξb
b)
Select AirCon Type:
Select aircon type in thermostat settings:
ΞS standard air condition (default)
ΞO Heat Pump with reverse valve. On = Cooling
ΞB Heat Pump with reverse valve. On = Heating
Note: there is a 3 minutes delays before the compressor restart
FA → F1 → FC
c)
Fan Logic:
FA is Automatic Fan (fan stop when aircon reaches the set point)
F1 is Fan Always On (no matter what is the set point)
FC is Fan work only in Cool mode (fan stop when aircon reaches set point and in heat mode)
E1 → E2 → E0
d)
Set point limiting range:
E1 (default)
E2
E0
a) Press
b) Hold + for 3 sec. to enter setup (light will flash)
set 'parameters' with
c)
d) press
e) Follow setup bellow
o
C
o
F
16-32
60-90
18-30
65-85
5-35
40-95
to Power On thermostat
to change setup mode