ADEMCO LYNXR24 Manuel de démarrage rapide
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} ADEMCO LYNXR24. ADEMCO LYNXR24 8 pages.
Également pour ADEMCO LYNXR24 : Manuel de démarrage rapide (8 pages)
®
8 /
LYNXR is not intended for UL985 Household Fire applications.
Introduction
This Quick Start Guide can help you install the rechargeable LYNXR and LYNXR24 quickly and easily by providing
the basic steps for installation using the built-in defaults. For more detailed information and important notes, refer
to the LYNXR/LYNXR24 Installation Instructions.
The following steps assume that one of the system's default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone
Table 1
1
-------
2
front door
3
back door
4
window
5
motion detector
6
-------
7
-------
8
-------
9
-------
26
loop 3 arm away
27
loop 2 disarm
28
loop 4 arm stay
29
loop 1 restore device 1
30
loop 3 arm away
31
loop 2 disarm
32
loop 4 arm stay
33
loop 1 restore device 1
92
duress
99
silent alarm
User Code
1-2-3-4
Install Code
4-1-1-2
Entering Program Mode: installer code + 8 0 0
Interactive Mode
* 56 Enhanced Zone Programming
* 83 Sequential Mode
*84 Assign Zone Voice Descriptors
Exiting Program Mode: * 99 allows re-entry into the Program mode using Installer Code + 8 0 0.
* 98 inhibits re-entry into the Programming mode using the Installer Code.
NOTES: • Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline
Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For
other applications or actions (e.g., using a pulsing siren), see the *80 Device Programming Menu Mode section of the Installation
Instructions.
• Primary report format for all tables is Ademco's Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary
reporting. Tables 1, and 3 use 4+1 format for secondary reporting.
• Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores
in their event logs.
4XLFN6WDUW*XLGH
Table 2
-------
front door
back door
Garage door
motion detector
smoke detector
-------
-------
-------
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 restore device 1
duress
silent alarm
1-2-3-4
4-1-1-2
Zone characteristics, report codes, and serial numbers
5800 Series transmitter serial numbers
Voice descriptors for each zone
/<1;5/<1;5
Table 3
-------
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
duress
silent alarm
1-2-3-4
4-1-1-2
Used to Program
K5484 7/00
Table 4
-------
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 restore device 1
duress
silent alarm
1-2-3-4
4-1-1-2