Mounting Fascia
1. The ventilation should be ducted through the roof space, ducting to an external soffit under the eaves or
grille in the slope of your roof.
Ducting can only run between joists, not across them.
2. Mark the position of the fascia with a pencil in a suitable posistion on the ceiling, making sure that it is
between joists.
3. Drill a 9mm hole through the ceiling along the edge of the pencil line. Now cut out the hole with a pad
saw.
4. Hold the fascia against the ceiling and mark the posistion of the fixing holes, fix the unit in place using suit-
able fixings - (not supplied)
5. Attach the flexible ducting with the metal hose clamps.
Ensure the ducting has a smooth flow towards the
motor body. Follow a simular procedure for the outside wall grille.
Extra ducting may be used to extend the
distance to the external grille but the performance will be reduced.
Mounting Fan Unit
Install the Cyclone Inline fan within the loft or ceiling space, ensuring the correct direction of air flow using
the arrows on the fan.
DO NOT COVER
the motor or LED driver with loft insulation. The fan is only suitable for
horizontal mounting
on a wall or floor. See fig A and fig B.Follow the visual aids below to mount the Fan unit.
min 1m
Do not mount duct or
g. A horizontal on a wall
g. B horizontal on a oor
motor vertically
Do not run the ducting over the joists, this will cause a build of condensation and reduce the
extraction rate. Ensure the ducting is run between joists to create smooth airflow.