HiB 33800 Manuel
4. Place frame in desired
location and mark fixing
holes.
6. Connect the flexible ducting to both sides of the Inline fan with the metal hose clamps. Ensure
there is a minimum of 1m straight ducting between fascia and fan.

Electrical Connection

Ensure the mains power supply to which the fan is being connected is turned off. This product is
designed to be connected to an on/off switch outside the bathroom, or to a ceiling mounted pull
cord switch.
1. Using a screw driver,
remove cover.
4
5. Fix frame to desired surface, using fixings suitable for
wall type. Then replace central unit and bracing clips.
2. Using a screw driver,
remove cable grip.
3. Feed cable through hole