The compressor circuit topology is selected using the TYPE switch.

Compression KNEE

The KNEE function determines the shape of the 529 Compressor's response curve at the onset of
compression.
The 529 Compressor has three (3) KNEE settings that control how the compressor transitions into
compression:
HARD: Sharp response curve
MEDium: Slightly rounded response curve
SOFT: Rounded response curve

HARD KNEE Compression

HARD: Sharp response curve
Immediate onset of compression (sudden transition to set ratio)
More aggressive and noticeable
Red LED
5 2 9 S t e r e o C o m p r e s s o r
TYPE: Toggle to select the compressor circuit topology
NEW: Engages the feed-forward topology (yellow LED)
OLD: Engages feed-back topology (green LED)