Example 2
Intention:
You want to activate a factory preset alert using another key than pre-programmed.
Summary
Employing a previously unused input (e. g. B3) you want to trigger included DIN-alert of the DMM 4650.
The functioning of the input A4 which is already utilized for the DIN-alert has to be maintained. The
new, additional start-key has been already connected to the port B, input 3 (page 30). It has to be
programmed in the trigger menu to activate the sequence "DIN-Alarm" (=S22).
Step By Step Programming
Enter the password for the user level 3 on the display,
using the four cursor keys (page 10) and confirm your
action with the "ok"-button.
If you have entered the correct password,
the display briefly shows this message and
then returns to the main menu.
After pressing this cursor key twice, the "Trigger" menu
appears. Confirm your selection by pressing the "ok"-
button.
The display shows that input 1 of port A is disabled.
You can always change the character on which the
blinking cursor is positioned.
Pressing the indicated key positions the cursor on "Port
B". The bottom line in the display shows the momentary
setting of port B, input 1.
Pressing the indicated key positions the cursor on the
number of the input.
Pressing the indicated cursor key twice selects input 3.
The bottom line in the display shows the momentary
setting of port B, input 3 which triggers sequence 25.
To start the required alarm-sequence 22, you have to
press the indicated cursor key twice so that "5" appears
in the display.
Pressing the indicated cursor key three times displays
the required sequence number (S22).
Press the soft key "set" to store the setting.
From now on, the external button of the input B3 triggers the sequence 22.
Pressing the "EXIT" key twice ceases the programming.
The display is dimmed and you are able to test the
functioning of the sequence (example 2).
Ù
×
Ú
Dynacord DMM4650
Userlevel 3
Ù
2x
×
Ú
Ù
×
Ú
Ù
×
Ú
Ù Ù
2x
× ×
Ú Ú
Ù
2x
×
Ú
Ù
×
Ú
EXIT
password?
Ø
****
Main-Menu
System-Setup
Main-Menu
Ø
Trigger
starttrg A.1 set
off
starttrg B.1 set
Ø
H >00,1s dyn S23
starttrg B.1 set
Ø
H >00,1s dyn S23
starttrg B.3 set
starttrg B.3 set
Ø Ø
H >00,1s dyn S25
H >00,1s dyn S25
starttrg B.3 set
Ø
H >00,1s dyn S25
starttrg B.3 set
Ø
H >00,1s dyn S22
3x
2x
ok
ok
ok