HIBLOW hp-120 Manuel - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} HIBLOW hp-120. HIBLOW hp-120 9 pages.
Également pour HIBLOW hp-120 : Manuel d'instruction (13 pages)

HIBLOW hp-120 Manuel
HP- 100 / 120
CAUTION
! 
●Be sure to unplug the pump unit. 
●When  performing  replacement  work,  the  pump  body  may  still  be  hot  and  you  could 
get burned. So please wait until the pump has cooled before handling. 
●Be  sure  to  remove  the  chamber  block  and  the  actuating  rod  before  replacing  the 
electromagnet. 
●It  is  better  to  let  an  experienced  technician  handle  the  soldering  process.  Take 
precautions against getting burned.
STEP
STEP
REMOVAL OF ELECTROMAGNET
1
1
Cut  the  wire  from  the  terminals  on  electromag-
nets with nippers. 
●It is recommended that you make a note of the wiring.
STEP
STEP
2
2
Loosen the screw, fixing SP switch and remove it . 
(There  are  hexagonal  nuts  at  SP  switch  side.  Be 
sure not to lose them as they fall inside the unit.)
STEP
STEP
3
3
Remove the nuts by the box driver. 
(8mm wrench) 
Pull out the electromagnet from the pump body.
8
REPLACING THE ELECTROMAGNET