Emergi-Lite DLM-2 Series Manuel - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Emergi-Lite DLM-2 Series. Emergi-Lite DLM-2 Series 2 pages. Decorative emergency lighting unit

Wall mount Conduit entry
1. Remove the top knockout on the top flange of the fixture (see figure 5).
2. Remove keyhole knockouts on the back plate and mount to the wall.
3. Secure conduit to knockout and feed wires into the fixture.
4. Make the proper connections (see figure 5):
a. For 120VAC, connect the black wire (120Vac) and white wire
(neutral) to the building utility.
b. For 277 VAC, connect the orange wire (277Vac) and white wire
(neutral) to the building utility.
5. Connect the red wire to the battery positive terminal (see figure 3).
6. Snap housing to back plate.
7. Restore power and press the test button.
Relamping
1. Snap off to remove lens.
2. Refer to the relamping information located near lamp holder for recom-
mended maximum wattage. Do not exceed this wattage.
3. Install the bulb.
4. Reinstall the lens.
Maintenance
None required. Replace the batteries as needed according to ambient
conditions. Equipment must be tested reguarly in accordance with local
codes.
Emergi-Lite®
Tel: (888) 552-6467
®
Fax: (800) 316-4515
Orange (277Vac)
Back plate
Housing
Figure 4
Back plate
Orange (277 Vac)
Conduit
connector
nut
Black
(120 Vac)
Top of
housing
Housing
Figure 5
www.emergi-lite.com
DLM-2 Series
White (neutral)
Junction box
Black
(120Vac)
Wire
connector
Slots for
junction box
Junction box
screws
Bulb
Lens
Conduit
(not ptovided)
Screw
Conduit
connector
Conduit
knockout
White (neutral)
Wire connector
Bulb
Lens
10/16 750.1329 Rev. B
2/2