CAUTION
! 
●Be sure to unplug the pump unit. 
●When performing replacement work, the pump body may be still hot and you may get 
burnt. Therefore, wait until the pump has been allowed to cool. 
●Be  sure  to  remove  the  chamber  block  and  the  actuating  rod  before  replacing  the 
electromagnet. 
●It is better to let an experienced technician handle the soldering process. 
  Take precautions against being burnt. 
●In case of HP-10/20, do the same way of replacing the electromagnet.
STEP
STEP
REMOVING THE ELECTROMAGNET
1
1
Cut  the  wire  from  the  terminals  on  the 
electromagnet with nippers.
●It is recommended that you make a note of the wiring.
STEP
STEP
2
2
Remove the nuts with the box driver. 
(7mm wrench.)
STEP
STEP
3
3
Pull out electromagnets from the pump body.
4