ADEMCO VISTA-15P Manuel de programmation - Page 5

Parcourez en ligne ou téléchargez le pdf Manuel de programmation pour {nom_de_la_catégorie} ADEMCO VISTA-15P. ADEMCO VISTA-15P 17 pages. Programming auto arming and disarming schedules
Également pour ADEMCO VISTA-15P : Manuel d'installation rapide (2 pages), Manuel de l'utilisateur (20 pages), Manuel de programmation (17 pages), Manuel d'installation rapide (2 pages), Manuel d'installation rapide (2 pages), Manuel de programmation (2 pages), Manuel rapide (2 pages)

ADEMCO VISTA-15P Manuel de programmation
∗ ∗ ∗ ∗ 88
Program Mode Lockout Options
0 = standard *98 installer code lockout (reentry only by [∗] + [#] within
50 seconds after power up)
1 = lockout [∗] + [#] reentry after *98 exit (reenter via installer code or
downloader only)
2 = not used
3 = lockout local programming after *98 exit (reenter by downloader only)
∗ ∗ ∗ ∗ 89
Event Log Full Report Code
See box above field *59 for report code entries.
∗ ∗ ∗ ∗ 90
Event Log Enables
NOTE : System messages are logged when any non-zero entry is made.
0 = None; 1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore;
4 = Bypass/Bypass Restore;
8 = Open/Close. Example: To select "Alarm/Alarm Restore", and
"Open/Close", enter 9 (1 + 8); To select all, enter #15.
∗ ∗ ∗ ∗ 91
Option Selection
Options: 0 = None
4 = AAV UL: must use ADEMCO UVCM module
8 = Exit Delay Restart/Reset UL: must be disabled
#+12 = AAV and Exit Delay Restart/Reset
SIA Guidelines: Exit Delay should be enabled.
V20PSIA/V15PSIA:
Options: Same as listed above.
Call Waiting Disable:
0 = call waiting not used
1 = call waiting disable digits (*70) entered in field *40; (when
selected, the system dials the entry in field *40 only on
alternate dial attempts; this allows proper dialing in the event
call waiting service is later canceled by the user).
∗ ∗ ∗ ∗ 92
Phone Line Monitor Enable
UL: see Inst. Instructions for requirements
NOTE: Output Device must either be programmed to be STOPPED in
field ✱80 or STOPPED by Code + # + 8 + output number.
Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14
= 14 min; #+15 = 15 min)
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as "1", plus programmed output device STARTS. If either
partition is armed, external sounder activates also.
∗ ∗ ∗ ∗ 93
Reports In Armed Period
Per Zone
(Swinger Suppression)
Restrict Report Pairs:
0 = Unlimited Reports
1 = 1 report pair
2 = 2 report pairs
SIA Guidelines: Must be set for option 1 or 2.
V20PSIA/V15PSIA:
Restrict Report Pairs: 1 = 1 report pair; 2 = 2 report pairs
Unlimited Reports Enable:
0 = restrict reports to the setting in entry 1
1 = unlimited reports for zones listed in zone list 7; (use zone list 7
to enter those zones that require unlimited reporting; these
zones ignore the setting in entry 1)
DOWNLOAD INFORMATION ( ✱ 94, ✱ 95)
∗ ∗ ∗ ∗ 94
Download Phone No.
|
|
|
|
|
|
|
|
|
Enter up to 20 digits, 0–9; #+11 for ' ✱ '; #+12 for '#'; #+13 for a 2-
second pause. Do not fill unused spaces. If fewer than 20 digits, exit
field by pressing ✱ . To clear entries from field, press ✱ 94 ✱ .
UL: downloading may be performed only if a technician is at the site.
∗ ∗ ∗ ∗ 95
Ring Count For Downloading
NOTE: Do not enter "0" if using 4285/4286 Phone Module.
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
[0]
[00]
|
[3]
[8, 0]
Options
V20PSIA/V15PSI
Call Wait Disable
[0,0]
1
[1,0]
Restrict
V20PSIA/V15PSIA
Report Pairs
Unlimited
Reports Enable
|
|
|
|
|
|
|
|
|
|
[15]
∗ ∗ ∗ ∗ 96
, ∗ ∗ ∗ ∗ 97
Initialize/Reset Defaults
This is a command, not a data field. See page 2.
∗ ∗ ∗ ∗ 98
Exit Commands
, *99
This is a command, not a data field. See page 2.
PAGER OPTIONS (✱160- ✱172)
∗ ∗ ∗ ∗ 160
Pager 1 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 161
Pager 1 Characters
|
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 162
Pager 1 Report Options
A
Part. 1 Part. 2 common
For each partition, select from the following options:
0 =
no reports sent
1 =
Opens/closes all users
4 =
All alarms and troubles
5 =
All alarms / troubles, and opens/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9, and
opens/closes for all users
∗ ∗ ∗ ∗ 163
Pager 2 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = 'Q'; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 164
Pager 2 Characters
|
|
|
|
|
2
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 165
Pager 2 Report Options
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 10 if using options 12 or 13).
∗ ∗ ∗ ∗ 166
Pager 3 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 167
Pager 3 Characters
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 168
Pager 3 Report Options
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 11 if using options 12 or 13).
∗ ∗ ∗ ∗ 169
Pager 4 Phone No.
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-sec pause
∗ ∗ ∗ ∗ 170
Pager 4 Characters
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
∗ ∗ ∗ ∗ 171
Pager 4 Report Options
Part. 1 Part. 2 common
See field *162 for reporting options. Select for each partition (use zone
list 12 if using options 12 or 13).
∗ ∗ ∗ ∗ 172
Pager Delay Option For Alarms
0 = none; 1 = 1 minute; 2 = 2 minutes; 3 = 3 minutes
This delay is for ALL pagers in the system.
– 5 –
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[0,0,0]
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
[3]