HIBLOW hp-80 Manuel de démarrage rapide - Page 2
Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} HIBLOW hp-80. HIBLOW hp-80 7 pages.
Également pour HIBLOW hp-80 : Manuel d'instruction (13 pages)
HP- 60/80
CAUTION
!
●Be sure to unplug the pump unit.
●Replace the diaphragms and the valves with new ones at least once a year to one and
a half year regularly in order to maintain their initial performance.
●For chamber block replacement, be sure to change both chamber blocks at the same time.
●The rod employs powerful permanent magnets. Therefore, be sure to remove your
watch and any other precision machines before operation as they may be affected by
the strong magnetic force.
●Do not put the actuating rod close to a magnetic card, magnetic disk or other magnetic
media as the data may be destroyed.
STEP
STEP
REMOVAL OF THE CHAMBER BLOCKS
1
1
To remove the upper housing.
(Refer to
Remove the sound absorber.
Pull out the L-tube from the casing block.
STEP
STEP
2
2
Remove the 4 screws holding the chamber block
and the casing block.
(4 screws on each side)
STEP
STEP
3
3
Remove 1 U-lock nuts from one side holding the
diaphragm mounting block to the rod.
●Use the nut driver to loosen (or tighten) the U-lock nut.
2
REMOVING UPPER HOUSING
Goodies Wastewater Supplies
Phone: 1300 282 181 Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210 35 Scenic Cr, Coomera QLD 4209
Email: [email protected] Web: www.goodies.net.au
REPLACING THE CHAMBER BLOCK
)