celesco MTA-5 Manuel de démarrage rapide - Page 3

Parcourez en ligne ou téléchargez le pdf Manuel de démarrage rapide pour {nom_de_la_catégorie} celesco MTA-5. celesco MTA-5 4 pages.

of the Celesco crimping pliers part number 9610035-0000. Squeeze the pliers
until the crimping pliers release to insure a strong crimp.
14.
Secure the crimp to the spool using Loctite 401, with the flat portion of the crimp
adhered to the spool.
15.
If the ball bearings are attached to the spool shaft on the spring arbor side, remove
and place the bearings in the hollow in the side plate.
16.
Reassemble the side plate and spool by aligning the slit on the spring arbor to the
spring. Rest the pin on the side plate, tilt down so the spring is in the arbor slit,
and rotate a small amount counter-clockwise to put a small amount of tension on
the spring. While maintaining tension, slide the spool until the pin drops into the
hole in the center of the ball bearings. Once done keep the spool and the side
plate together with the small amount of tension on the spring.
17.
Replace the spool/side plate assembly in the housing.
18.
Tighten the set screws enough to keep the side plate in place but loose enough it
can be rotated.
19.
Replace the end plate pot side aligning the marks created during disassembly.
20.
Tighten the set screws to keep the end plate pot side in place bot loose enough it
can be rotated.
21.
Insert a pair of needle nose pliers into the two blind holes on the side plate and
rotate counterclockwise, reeling the cable into the unit. Keep rotating until the
cable snubber rests against the cable exit in the housing (about one full turn).
22.
Rotate side plate 3 more turns counterclockwise. This will place initial cable
tension on the spool.
23.
Tighten the 3 set screws evenly to fasten the side plate.
24.
Extend and retract the cable checking for smoothness.
25.
Apply 10 volts between the brown (+ in) wire and the orange (– out) wire. Place
a voltmeter between the Orange (-) and the red (+ out).
26.
The output should be between .030 to .080 volts. If not, rotate the potentiometer
side plate using a pair of needle nose pliers via the two blind holes on the cover
until the output is correct.
27.
Tighten the 3 set screws on the end plate pot side evenly.
Page 3 of 4