NEMA 4X VoIP Telephones
I/O
Inputs
Four clean dry-contact auxiliary inputs have been provided for customer use. Terminations for these
inputs are provided on terminal block P12. Refer to Figure 7. Connect each input between the desired
input (
) and common (
INPUT 1–4
Tronics Pub. 42004-481, "VoIP Telephone Configuration Guide" for programming instructions for these
inputs.
Inputs have an internal pull-up resistor and need to be 3.3 V dc tolerant.
Outputs
Two outputs have been provided for customer use. Terminations for these outputs are provided on
connector
on the relay PCBA. Refer to Figure 7.
P2
The function of each output is configurable. Outputs can be configured for one of the following modes:
On, Off, Pulse, Mute, Ring, Call, Connect, Hook, In Use, Ring Cadence, Ring Out, Page, Registered, or
Emergency. In some modes, the duration of the activation or on/off times can also be set. Refer to the
"Logic Settings" section of Pub. 42004-481, "VoIP Telephone Configuration Guide" for more details.
Relay capacity is 5 A at 30 V dc or 120 V ac.
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-520A.docx
03/17
) on terminal block P12. Refer to the "Inputs" section of GAI-
GND
Table 2. Auxiliary Inputs—Terminal Block P12
Pin
Label
1
IN4
2
COM
3
IN3
4
COM
5
IN2
6
COM
7
IN1
8
COM
Table 3. Output Contacts—Connector P2
Pin
Label
1
C2
2
NO2
3
C1
4
NO1
Function
Input 4
Common
Input 3
Common
Input 2
Common
Input 1
Common
Description
Common Output 2
Normally Open Output 2
Common Output 1
Normally Open Output 1
Pub. 42004-520A