GAI-Tronics Commander CB Manuel d'installation et d'utilisation - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} GAI-Tronics Commander CB. GAI-Tronics Commander CB 20 pages. Weather resistant telephones

GAI-Tronics Commander CB Manuel d'installation et d'utilisation
Only fit a second gland if a separate cable is required to the phone (for
example for an additional hook contact).
2. Select the appropriate sized gland:
Use the smaller gland for cables
diameters 4 - 7mm.
Use the larger gland for cable
diameters 8 - 13mm.
3. From the outside of the case, insert
the selected gland into the threaded
cable entry hole and tighten, so that
its sealing washer is compressed
against the enclosure surface.
4. Proceed with chosen mounting method below

5.2. Titan

As standard, Titan with rear enclosure is supplied with 2 cable glands with
sealing washers, 4 countersunk screws with wall plugs and a 3mm Allen key.
Titan telephones supplied for flush mounting have no rear enclosure – see
section 5.2.3 below.
5.2.1
1. Using a suitable tool, punch out the 4 holes in the rear enclosure,
taking care not to damage or dislodge the plastic bushes. Only four
8
Wall mounting
Titan CB, Commander CB