751-905 SmartSeries
Speaker Amplifier
Installation
CAUTION
Do not install this equipment in hazardous areas other than those indicated
on the approval listing in the "Specifications" section of this manual. Such installation may cause a
safety hazard and consequent injury or property damage.
WARNING
Do not disconnect equipment while circuit is energized.
®
The SmartSeries
751-905 Speaker Amplifier plugs directly into any standard GAI-Tronics Page/Party
Series enclosure. Use extra care not to damage the protruding latch wings of connector J2 located on the
bottom edge of the amplifier during installation. It also plugs into standard SmartSeries
®
as a SmartSeries
station RTU enclosure or an enclosure that houses a party line EOL Module.
When installing the assembly in one of these enclosures, you must also connect the 10-conductor keyed
ribbon cable to J2 on the bottom of the Speaker Amp/Power Supply PCBA. Be sure that the red line on
the edge of the cable lines up with J2-pin 1.
Ensure that the connectors mate securely and then tighten the four screws in the corners of the front panel.
For continued IP 66 protection, torque setting for securing the amplifier into the enclosure should be 10 to
12 in-lbs. or 1.13 to 1.36 n-m.
Operation
The 751-905 SmartSeries
and supports other optional features listed below.
Optional Features
The following features are available as options to the standard configuration of a station used in an
ADVANCE system and installed in a standard SmartSeries
be configured. Contact the GAI-Tronics Field Service Department at 800-492-1212 inside the USA or
610-777-1374 outside the USA for further information about these features.
The Selected Page Destination feature allows the manual selection of one of four page destinations.
The Supervised Input feature allows the monitoring and supervision of one or two initiating device
circuits (IDCs), initiating an alarm when the supervised device is activated.
The Power Relay Module provides a relay contact output, typically to switch power to a visual
signaling device, for directed or relay group operation. Supervision of the controlled device's cable
can also be enabled.
f:\standard ioms - current release\42004 instr. manuals\42004-686l2d.doc
03/12
®
Speaker Amplifier amplifies incoming pages, provides speaker supervision,
®
or a custom enclosure. These features can
Pub. 42004-686L2D
5 of 11
P