Hickory N/5.5 G Manuel d'installation - Page 8

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Hickory N/5.5 G. Hickory N/5.5 G 18 pages. Hickory rotisseries installation manual

1.8
Orifice Diameters, Electrode Gap Settings, and Air Intake Settings
Type N/ 5.5 G
Gas / Pressure
inches W.C.
Natural / 5.5"
Propane / 11"
Butane / 11"
1.9
Changing Gas Orifices on the Gas Generators
The N/5.5 Gas unit has one infra-red gas generators. These generators use ceramic radiating
plates.
The burner orifice can be removed and replaced using a 7/16" wrench. The orifice must be
sealed and tightly in place.
Alternate Opening for
Inlet Pipe
Gas Inlet Pipe
Orifice Size
Ø in drill size
#46
#55
#55
Burner
Orifice
Venturi
Top View Gas Generator
4900 Westside Avenue, North Bergen, New Jersey 07047
Tel: [201] 223-0050 Fax: [201] 223-0950
Hickory Industries, Inc.
Electronic Ignition
Electrode Gap
1/8" Between rods
1/8" Between rods
and Burner surface
1/8" Between rods
1/8" Between rods
and Burner surface
1/8" Between rods
1/8" Between rods
and Burner surface
N/5.5 Installation 8/5/97
Page 8 of 18