2.3) Specifications
Table 1: Specifications datasheet
(g)
Full scale
acceceleration
(Hz)
Frequency
range (±3dB)
(%)
Non-linearity
(full scale)
(μg/
√Hz)
Noise (in band)
(mV/g)
Scale factor
(nominal)
(g)
Shock
survivability
Environmental
Table 2: Environmental specifications datasheet
Operating Voltage
Operating Temperature
Operating Current Consumption mA
1002SE
1004SE
1008SE
±2
±4
±8
1,500
1,500
1,500
0.1
0.1
0.1
25
25
25
400
200
100
5,000
5,000
5,000
Protection Level
Isolation
1010SE
1020SE
1040SE
±10
±20
±40
1,500
1,500
1,500
0.1
0.1
0.1
80
80
110
80
40
20
5,000
5,000
5,000
6 V
-40 °C to +100 °C
Case isolated
1050SE
1100SE
1200SE
±50
±100
3,000
3,000
3,000
0.1
0.1
130
220
40
20
5,000
6,000
6,000
IP 68
–
20 V
7 mA
1500SE
±200
±500
3,000
0.1
0.1
550
1,200
10
4
6,000
5