Automation Correct Coal-trol Digital TS2 Manuel d'instruction - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Automation Correct Coal-trol Digital TS2. Automation Correct Coal-trol Digital TS2 16 pages. Automation correct coal-trol digital – model ts2 thermostat

Instruction Manual
Page 2
Coal-trol Digital™ – Model TS2 THERMOSTAT

Coal-trol Digital Feature Overview

The Coal-trol Digital System is a complete control system designed for automatically fed stoker
stoves and furnaces utilizing anthracite fuel. The stove-mounted Control Module and the wall-
mounted Coal-trol Thermostat work together to supervise all stove operations and maintain room
temperature to within ±1°F of the desired setting.
The Control Module controls the coal feed rate, combustion blower fan, convection blower fan, fire
igniter (additional hardware required when available).
All connections to stove blowers, motors, and safety interlocks are done through standard
120VAC cord receptacles.
The Control Module has a lighted power On/Off switch and 120VAC cords for all controlled loads.
The Coal-trol Thermostat may be located up to 100 ft. from the Control Module. Proper
temperature control only requires that the heat generated by the stove is readily communicated
to the thermostat. (A forced air furnace located in the basement with the thermostat mounted
upstairs can work fine).
Fuel feed is continuously adjusted to maintain room temperature as set on the Coal-trol
thermostat. The Convection blower is automatically started and continuously adjusted to match
the heat output of the stove.
Two temperature setbacks automatically change the temperature at prescribed times set by the
user on a 24 hour time cycle.
A room high temperature limit shuts off the stove if feeder failure occurs.
The initial setup of minimum and maximum feed rates, and selection of either dual-motor or single
motor (Tri-Burner) stoker styles, allow Coal-trol Digital application to a wide variety of stove
configurations and brands.
A One-touch Feed mode assists in starting a fire by continuously stoking coal for 10 minutes at a
100% rate.
All settings, except for time of day clock, are maintained during power loss without batteries.
Power loss ride-through allows the thermostat to continue stove operation if power is restored
within 2 hours.
Test Mode sequences all motors and blowers to assist in installation and troubleshooting.
The Coal-trol Digital TS2 Thermostat features an LCD display, one LED indicator, and 3
pushbuttons for indication and control of all settings.
Automation Correct LLC
www.automationcorrect.com
6/2006 R0